Each archive configuration word has the following bitmap structure:
Bit
Description
0
Period select, hourly
1
Archive upon period end
2
Archive upon event
3
Reserved
4
Reset resettable accumulator 1 upon period end
5
Reset resettable accumulator 2 upon period end
6
Reset resettable accumulator 3 upon period end
7
Reset resettable accumulator 4 upon period end
8
Reset resettable accumulator 1 upon event
9
Reset resettable accumulator 2 upon event
10
Reset resettable accumulator 3 upon event
11
Reset resettable accumulator 4 upon event
12
Reserved
13
Reserved
14
Reserved
15
Reserved
Note: Bit 0 must be set only for the hourly archives.
Changes made directly to the Modbus table in this manner are not automatically
made to your open AFC configuration. To incorporate these changes into your
configuration so that they may be saved in the AFC file on your hard disk, you
must read back the meter configuration from the module after making the change
by using the "Read Configuration" button on the Meter Configuration window.