11.6.6 Pulse (Linear) Meter with Liquid Product

Start Offset

End Offset

Data Format

Type

Description

10

11

Accumulator Snapshot

Accumulator totalizer, net

12

13 Floating

point

Snapshot

Accumulator residue, net

14

15

Floating point

Flow weighted average

Flow rate, net

16

17

Floating point

Flow weighted average

Temperature

18

19

Floating point

Flow weighted average

Pressure

20

21

Floating point

Flow weighted average

K-Factor

22

23

Floating point

Flow weighted average

Meter Factor

24

25

Floating point

Flow weighted average

Density Input

26

Word

Flow

weighted

average

Water content, % e-2

27

Word

Flow

weighted

average

Corrected density (scaled integer)

28

Word

Flow

weighted

average

CTL e-4

29

Word

Flow

weighted

average

CPL e-4

This manual is related to the following products: