ProSoft Technology PTQ-AFC User Manual
Page 176
Backplane Communication
PTQ-AFC ♦ Modicon Quantum Platform
User Manual
Liquid and Gas Flow Computer for Hydrocarbon Products
Page 176 of 259
ProSoft Technology, Inc.
June 23, 2011
The Modbus Pass-Thru block received from the module has the following
structure:
Offset
Description Type
Comments
0
Pass-Thru transaction
present
Input
1
Pass-Thru transaction
0-word/1-bit select
Input
2
Register Address
Input
3
Number of Registers
Input
4 to
126
Data.
Input
When word-swap (Supervisory output word 11) is
applied to a data packet containing an odd number of
words, the last word is swapped with a word of zero.
The Modbus protocol limits the packet to 125 words of
data; the extra word here allows for word-swap to be
applied to a 125-word data packet.
9.1.6 Modbus
Master
Block
The Modbus master block can be used by the processor to issue a Modbus
master command to a remote Modbus slave device. Configure Port 3 as a
Modbus master device. This block is optional, and must be defined only if the
application intends to use this feature.
The processor must set the following register from the Supervisory Output Block
to 1 in order to issue the Modbus master command to a remote Modbus slave:
Offset
Description Type
Comments
4
Issue Master Transaction
Signal
The Modbus master block configures the Modbus command to be sent to the
remote slave address.
Offset
Description Comments
0
Slave Address
1
Direction and register bank
2
Data Item Size and Swap Options
3
Register Address
4
Number of Data Items
5
Error Code
6 to 124
Data