ProSoft Technology PTQ-AFC User Manual
Page 185
PTQ-AFC ♦ Modicon Quantum Platform
Backplane Communication
Liquid and Gas Flow Computer for Hydrocarbon Products
User Manual
ProSoft Technology, Inc.
Page 185 of 259
June 23, 2011
You can use this data type for your own Quantum program. The following data
types are defined:
Data Types
Description
METER_DIFF_GAS_VAR
Variables for Differential/Gas applications
METER_DIFF_GAS_RES
Results for Differential/Gas applications
METER_LINEAR_GAS_VAR
Variables for Linear/Gas applications
METER_LINEAR_GAS_RES
Results for Linear/Gas applications
METER_DIFF_LIQ_VAR
Variables for Differential/Liquid applications
METER_DIFF_LIQ_RES
Results for Differential/Liquid applications
METER_LINEAR_LIQ_VAR
Variables for Linear/Liquid applications
METER_LINEAR_LIQ_RES
Results for Linear/Liquid applications
ANALYSIS
Molar Analysis
METER_SIGNALS
Meter Signals
MODBUS_GATEWAY
Modbus Gateway
ARCHIVE_DIFF_GAS
Default Archive definition for Differential/Gas applications
ARCHIVE_LINEAR_GAS
Default Archive definition for Linear/Gas applications
ARCHIVE_DIFF_LIQ
Default Archive definition for Differential/Liquid
applications
ARCHIVE_LINEAR_LIQ
Default Archive definition for Linear/Liquid applications
MODBUS_MASTER
Modbus Master
MODBUS_PASS_THRU
Modbus Pass-Thru
The data type definition file is listed below:
TYPE
METER_DIFF_GAS_VAR:
STRUCT
Reserved: INT;
Temperature: REAL ;
Pressure: REAL;
DifferentialPressure: REAL;
END_STRUCT;
END_TYPE
TYPE
METER_DIFF_GAS_RES:
STRUCT
Alarms: INT;
Reserved: INT;
NetAccumulator: DINT ;
NetFlowRate: REAL;
GrossFlowRate: REAL;
Fpv: REAL;
Cprime: REAL;
END_STRUCT;
END_TYPE
TYPE
METER_LINEAR_GAS_VAR:
STRUCT
Reserved: INT;
Temperature: REAL ;
Pressure: REAL;
PulseCount: DINT;
Reserved1: INT;
Reserved2: INT;