MVI56E-MNETC ♦ ControlLogix Platform
Configuring the MVI56E-MNETC Module
Modbus TCP/IP Client Enhanced Communication Module
User Manual
ProSoft Technology, Inc.
Page 65 of 183
February 3, 2013
2.4
Downloading the Project to the Module
Note: For alternative methods of connecting to the module with your PC, refer to
Using CIPconnect to Connect to the Module (page 66) or Using RSWho to
Connect to the Module (page 75).
In order for the module to use the settings you configured, you must download
(copy) the updated Project file from your PC to the module.
1 In the tree view in ProSoft Configuration Builder, click once to select the
MVI56E-MNETC module.
2 Open the P
ROJECT
menu, and then choose M
ODULE
/
D
OWNLOAD
.
This action opens the Download
dialog box. Notice that the Ethernet address
field contains the temporary IP address you assigned previously. ProSoft
Configuration Builder will use this temporary IP address to connect to the
module.
Click T
EST
C
ONNECTION
to verify that the IP address allows access to the
module.
3 If the connection succeeds, click D
OWNLOAD
to transfer the Ethernet
configuration to the module.
If the Test Connection procedure fails, you will see an error message. To correct
the error, follow these steps.
1 Click OK
to dismiss the error message.