This action opens the Select Module dialog box. Enter generic in the text box
and select the G

ENERIC

1756

M

ODULE

. If you're using an earlier version of

RSLogix, expand O

THER

in the Select Module dialog box, and then select the

G

ENERIC

1756

M

ODULE

.

2 Click C

REATE

. This action opens the New Module dialog box.

3 Enter the Name, Description and Slot options for your application. You must

select the Comm Format as D

ATA

-

INT in the dialog box, otherwise the

module will not communicate. Click OK to continue.

Parameter

Value

Name

Enter a module identification string. Example: MNETC_2

Description

Enter a description for the module. Example: M

ODBUS

TCP/IP

C

LIENT

E

NHANCED

C

OMMUNICATION

M

ODULE

Comm Format

Select D

ATA

-INT.

Slot

Enter the slot number in the rack where the MVI56E-
MNETC module is located.

Input Assembly Instance

1

Input Size

250

Output Assembly Instance

2

Output Size

248

Configuration Assembly Instance

4

Configuration Size

0