beautypg.com

ProSoft Technology MVI56E-MNETC User Manual

Page 53

background image

MVI56E-MNETC ♦ ControlLogix Platform

Configuring the MVI56E-MNETC Module

Modbus TCP/IP Client Enhanced Communication Module

User Manual

ProSoft Technology, Inc.

Page 53 of 183

February 3, 2013

Command Entry Formats
The following table shows the structure of the configuration data necessary for
each of the supported commands.

1

2

3

4

5

6

7

8

9

10

Enable

Code

Internal

Address

Poll Interval

Time

Count Swap

Code

IP

Address

Serv

Port

Slave

Node

Function Code

Device
Modbus

Address

Code

Register
(bit)

1/10th
Seconds

Bit
Count

0

IP
Address

Port
#

Address Read Coil (0x)

Register

Code

Register
(bit)

1/10th
Seconds

Bit
Count

0

IP
Address

Port
#

Address Read Input (1x)

Register

Code

Register 1/10th

Seconds

Word

Count

Code IP

Address

Port

#

Address Read Holding

Registers (4x)

Register

Code

Register 1/10th

Seconds

Word
Count

0

IP
Address

Port
#

Address Read Input

Registers (3x)

Register

Code

1 bit

1/10th
Seconds

Bit
Count

0

IP
Address

Port
#

Address Force (Write)

Single Coil (0x)

Register

Code

1 bit

1/10th
Seconds

Word
Count

0

IP
Address

Port
#

Address Preset (Write)

Single Register

(4x)

Register

Code

Register
(bit)

1/10th
Seconds

Bit
Count

0

IP
Address

Port
#

Address Force (Write)

Multiple Coil (0x)

Register

Code

Register 1/10th

Seconds

Word

Count

0

IP

Address

Port

#

Address Preset (Write)

Multiple Register
(4x)

Register

The first part of the record is the module information, which relates to the MVI56E
module, and the second part contains information required to interface to the
server device.