PLANET SGSW-24040 User Manual
Page 288
User’s Manual of SGSW-24040 / 24240 Series
288
Figure 4-14-1 LLDP Configuration page screenshot
The page includes the following fields:
LLDP Parameters
Object
Description
•
Tx Interval
The switch is periodically transmitting LLDP frames to its neighbors for having the
network discovery information up-to-date. The interval between each LLDP
frame is determined by the Tx Interval value. Valid values are restricted to 5 -
32768 seconds.
Default: 30 seconds
This attribute must comply with the following rule:
(Transmission Interval * Hold Time Multiplier)
≤65536, and Transmission Interval
This manual is related to the following products: