Switch# configure terminal

Switch (config)# loop-protect

4.2.99 loop-protect shutdown-time

Command:

loop-protect shutdown-time <0-604800>

loop-protect Loop protection configuration

shutdown-time Loop protection shutdown time interval

<0-604800> Shutdown time in second

Default:

180

Usage Guide:

To configure shutdown time interval of Loop Protection

Example:

To configure shutdown time interval (888) of Loop Protection

Switch# configure terminal

Switch (config)# loop-protect shutdown-time 888

4.2.100 loop-protect transmit-time

Command:

loop-protect transmit-time <0-10>

loop-protect Loop protection configuration

transmit-time Loop protection transmit time interval

<1-10> Transmit time in second

Default:

5

Usage Guide:

To configure Transmission Time of Loop Protection

Example:

To configure Transmission Time (8) of Loop Protection