3-30
KLR091313
NOTE: IP Address is in use.
Click CONFIGURE LAN and choose another IP to correct.
An IP address that is not already in use must be entered and submitted, otherwise the browser
will lock, requiring the browser to be closed and reopened.
3.3.6.6
OPERATING THE UNIT USING WEB INTERFACE [E-SERIES MODELS ONLY]
To operate the unit, click the OPERATE INSTRUMENT box at the left. A simulated front panel at
the top of the screen shows 1) output voltage and current, 2) CV or CC if the unit is in constant
voltage or constant current mode, respectively (** is displayed if the output is off, meaning the
unit is in neither CV nor CC mode), and 3) whether the output is on or off. An ON/OFF button
can be clicked to turn the output on or off. A small white dot below the voltage display flashes to
indicate the web page is communicating with the unit. If a fault condition exists, an alert window
indicates the type of fault, and operation via the web is disabled. When the fault is corrected,
click OK to close the alert window and resume operation via the web.
NOTE: If the OPERATE INSTRUMENT password has been set (see PAR. 3.3.6.5), you will be
prompted to enter the password before the OPERATE INSTRUMENT page settings
can be changed.
If the unit has been set to Analog control mode, the OPERATE INSTRUMENT page displays
only voltage, current, CV or CC mode, and output state. The unit can not be controlled via the
LAN interface and the message “Analog Remote Control” is displayed on the open web page.
The functions that the user can modify are listed on the black menu bar below the representa-
tion of the front panel: Output, Protection, Save/Recall, Reset, List, and Limit Model, and are
described in the following paragraphs.
NOTE: Once data in a field has been changed, clicking the browser’s BACK button will cause
all fields to revert to their previous values.
FIGURE 3-7. WEB INTERFACE OPERATE INSTRUMENT PAGE