beautypg.com

16 unit configuration, 17 utility function, Unit configuration -16 – KEPCO KLR Series User Manual User Manual

Page 56: Utility function -16, Ar. 3.2.16), Ar 3.2.16)

background image

3-16

KLR091313

3.2.16

UNIT CONFIGURATION

The Configuration Function identifies the firmware version, the KLR model, and the options
installed.

1. If the status display shows SET, tap either the CURRENT or VOLTAGE controls to take the

unit out of setpoint mode (status display goes from SET to blank).

2. Using a thin tool (e.g., a paper clip), press the FUNCTION switch once, then rotate either the

VOLTAGE or CURRENT control until the status display reads CNFG.

3. Tap DC OUTPUT switch to enter the submenu, then rotate either the VOLTAGE or CUR-

RENT control to view the following configuration information:

• When the status display reads VERS, the DC VOLTS display identifies whether the firm-

ware is the factory shipped firmware (Pri displayed) or field updated firmware (SEC dis-
played). The DC AMPERES display shows the firmware version. This information
cannot be changed directly by the user.

• When the status display reads KLR, the DC VOLTS display shows the model voltage rat-

ing (e.g, 75.00 for KLR 75-32) and the DC AMPERES display shows the model current
rating (e.g, 32.00 for KLR 75-32). This information cannot be changed by the user.

• If the status display reads RODC, this indicates the unit is an R-Option model that has

RODC (Rapid Output Discharge Circuit) installed.

• If the status display reads LAN, this indicates the unit is an E-Series model that has the

RS 232 port replaced by an ethernet-enabled LAN communication port.

• When status display reads RTN, tap DC OUTPUT switch to exit submenu and return to

previous menu

3.2.17

UTILITY FUNCTION

The Utility Function provides additional system information or access to special functions.
These are described below.

1. If the status display shows SET, tap either the CURRENT or VOLTAGE controls to take the

unit out of setpoint mode (status display goes from SET to blank)

2. Using a thin tool (e.g., a paper clip), press the FUNCTION switch once, then rotate either the

VOLTAGE or CURRENT control in either direction until status display reads UTIL.

3. Tap DC OUTPUT switch once, then rotate either the VOLTAGE or CURRENT control in

either direction to select the function identified in the status display (see below). Tap the DC
OUTPUT
switch to enter the submenu.

RELY - Relay Control (see PAR. 3.2.17.1)

QkBT - Quick Boot (see PAR. 3.2.17.2)

ADJ - Coarse/Fine Adjustment Preference (see PAR. 3.2.4)

SYST - System Configuration (see PAR. 3.2.17.3)