KEPCO KLR Series User Manual User Manual
Kepco, User manual, Klr series
KEPCO
®
THE POWER SUPPLIER™
MODEL
USER MANUAL
ORDER NO.
REV. NO.
KEPCO, INC. z 131-38 SANFORD AVENUE z FLUSHING, NY. 11355 U.S.A. z TEL (718) 461-7000 z FAX (718) 767-1102
email: [email protected] z World Wide Web: http://www.kepcopower.com
KEPCO INC.
An ISO 9001 Company.
KLR SERIES
POWER SUPPLY
2400 WATT PROGRAMMABLE POWER SUPPLY
KLR SERIES
POWER SUPPLY
©2013, KEPCO, INC
P/N 243-1297-a
IMPORTANT NOTES:
1)
This manual is valid for the following Firmware Versions:
FIRMWARE VERSION
NOTE.
10.07 and higher
2)
A Change Page may be included at the end of the manual. All applicable changes and
revision number changes are documented with reference to the equipment serial num-
bers. Before using this Instruction Manual, check your equipment serial number to identify
your model. If in doubt, contact your nearest Kepco Representative, or the Kepco Docu-
mentation Office in New York, (718) 461-7000, requesting the correct revision for your
particular model and serial number.
3)
The contents of this manual are protected by copyright. Reproduction of any part can be
made only with the specific written permission of Kepco, Inc.
Data subject to change without notice.
Document Outline
- SECTION 1 - INTRODUCTION
- SECTION 2 - INSTALLATION
- SECTION 3 - OPERATION
- SECTION 4 - CALIBRATION
- FIGURE 1-1. KLR Series Power Supply
- SECTION 1 - INTRODUCTION
- 1.1 Scope of Manual
- 1.2 General Description
- 1.3 Options
- 1.3.1 Rapid Output Discharge Circuit (RODC) Option (R Suffix)
- TABLE 1-1. Rapid Output Discharge Circuit Improvement in Output Response Time
- 1.4 Specifications
- TABLE 1-2. Model Parameters
- TABLE 1-3. KLR Specifications
- FIGURE 1-2. KLR Series Power Supply, Mechanical Outline Drawing
- 1.5 Features
- 1.5.1 Local Control
- 1.5.2 Remote Control
- 1.5.2.1 Digital Programming
- 1.5.2.2 Analog Programming
- 1.5.3 Digital Calibration
- 1.5.4 Overvoltage/Overcurrent Protection
- 1.5.5 User-defined Voltage/Current Limits (limit Models)
- 1.5.6 Storage of User-Programmed Active Settings
- 1.5.7 User-Programmed Sequences
- 1.5.8 Last Setting Recall
- 1.5.9 Built-in Protection
- 1.5.10 Internal Relay
- 1.5.11 Master/Slave Control [standard models Only]
- 1.6 Equipment Supplied
- TABLE 1-4. Equipment Supplied
- 1.7 Accessories
- 1.8 Safety
- TABLE 1-5. Accessories
- TABLE 1-6. Safety Symbols
- SECTION 2 - INSTALLATION
- 2.1 Unpacking and Inspection
- 2.2 Terminations and Controls
- 2.2.1 Front Panel Controls and Indicators.
- FIGURE 2-1. KLR Series, Front Panel Controls and Indicators
- TABLE 2-1. Controls, and Indicators
- 2.2.2 Rear Panel Connectors and Switches.
- TABLE 2-2. Analog I/O Switch Functions
- FIGURE 2-2. KLR Series, Rear Panel Switch and Connectors
- TABLE 2-3. IEEE 488 Port Connector (J4) Pin Assignments
- TABLE 2-4. RS 232 Port Connector (J3) Pin Assignments [Standard Models Only]
- TABLE 2-5. LAN Port Connector (J7) Pin Assignments [E-Series Models Only]
- TABLE 2-6. Control Input Terminal block Assignments
- TABLE 2-7. Analog I/O Connector (J2) Pin Assignments
- 2.3 Source Power Requirements
- 2.4 Cooling
- 2.5 Preliminary Operational Check
- 2.6 Installation
- 2.6.1 Rack Mounting
- 2.7 Wiring Instructions
- 2.7.1 Safety Grounding
- 2.7.2 Source Power
- 2.7.2.1 Current Rating
- 2.7.2.2 Connections
- 2.7.3 D-C Output Grounding
- 2.7.4 Power Supply/Load Interface
- 2.7.5 Load Connection - General
- 2.7.5.1 Local Sensing/Remote Sensing Select
- FIGURE 2-3. Remote Sensing
- 2.7.6 Series Operation
- 2.7.7 Parallel Operation
- FIGURE 2-4. Series Connection using Remote Sensing
- FIGURE 2-5. Parallel Connections Using Remote Sensing
- 2.7.7.1 Load Sharing
- 2.7.8 Master/Slave Configurations [Standard Models Only]
- 2.7.9 Analog I/O Connections
- 2.8 Digital Connections
- 2.8.1 GPIB Connections
- 2.8.2 RS 232 Connections [Standard Models Only]
- 2.8.3 LAN Connections [E-Series Models Only]
- SECTION 3 - OPERATION
- 3.1 General
- 3.2 Local Mode Operation
- 3.2.1 Turning the Power Supply On
- TABLE 3-1. Power-up Built-in Test Error Codes
- 3.2.2 Setting Local/Remote Mode
- 3.2.2.1 Remote with Local (Front Panel) Lockout
- 3.2.3 Menu Structure
- 3.2.4 Setting VOLTAGE and CURRENT Control Coarse/Fine Preference
- FIGURE 3-1. Function Switch Menu Structure
- 3.2.5 Enabling/Disabling Output Power
- 3.2.6 Enabling/Disabling the Output using Remote Inhibit
- 3.2.7 Checking Voltage/Current Setpoints
- 3.2.8 Password Protected Functions
- 3.2.9 Defining a Limit Model
- 3.2.10 Setting voltage or current
- 3.2.10.1 Real-time Voltage/Current Adjustment
- 3.2.10.2 Setpoint Adjustment
- 3.2.10.3 Last Setting Recall
- 3.2.11 Viewing/Changing Overvoltage or Overcurrent Protection Values
- 3.2.12 Changing GPIB Address
- 3.2.13 Changing RS 232 Baud Rate [Standard Models Only]
- 3.2.14 Setting up Master/Slave Configurations [Standard Models Only]
- 3.2.14.1 Configure power supply as Slave [Standard Models Only]
- 3.2.14.2 Configure power supply as Master [Standard Models Only]
- 3.2.14.3 Operating the Master/Slave Configuration [Standard Models Only]
- 3.2.14.4 Restoring the Master/Slave Configuration to Standalone operation [Standard Models Only]
- 3.2.15 LAN Interface Configuration [E-series Models Only]
- 3.2.16 Unit Configuration
- 3.2.17 Utility Function
- 3.2.17.1 Internal Relay Control
- 3.2.17.2 Quick Boot
- 3.2.17.3 System Configuration Functions
- 3.2.17.3.1 Remote Inhibit Polarity
- 3.2.17.3.2 Fault Recovery Mode
- TABLE 3-2. Fault Recovery Configuration
- FIGURE 3-2. Fault Recovery Configuration Display
- 3.2.17.4 Analog Output Full Scale Calibration
- 3.2.17.5 Analog Input Full Scale Calibration
- 3.2.17.6 Calibration
- 3.3 Remote Mode Programming Using Digital Interfaces
- 3.3.1 Factory Default Settings
- 3.3.1.1 GPIB Factory Defaults
- 3.3.1.2 RS 232 Factory Defaults [Standard Models Only]
- 3.3.1.3 LAN Factory Defaults [E-Series Models Only]
- 3.3.2 Additional Functions Not Available from the Front Panel
- 3.3.3 Remote Programming Using the IVI-COM Instrument Driver
- 3.3.4 Remote Programming Using the LabView G Instrument Driver
- 3.3.5 Remote Programming Using the VXI plug&play Instrument Driver
- 3.3.6 Remote Programming Using the Web Interface [E-series Models Only]
- 3.3.6.1 Troubleshooting LAN Communication Problems.
- 3.3.6.2 Finding Kepco Power Supplies on the LAN [E-Series Models Only]
- FIGURE 3-3. PS Find Screen
- 3.3.6.3 Launch Web Interface [E-Series Models Only]
- FIGURE 3-4. Web Interface Home Page (Unit Description)
- 3.3.6.4 Instrument Configuration Using Web Interface [E-Series Models Only]
- FIGURE 3-5. Web Interface Configure Instrument Page
- 3.3.6.5 LAN Configuration Using Web Interface [E-Series Models Only]
- FIGURE 3-6. Web Interface Configure LAN Page
- 3.3.6.6 Operating The Unit Using Web Interface [E-Series Models Only]
- FIGURE 3-7. Web Interface Operate Instrument Page
- 3.3.6.6.1 Changing the Output [E-Series Models Only]
- 3.3.6.6.2 Changing Protection [E-Series Models Only]
- FIGURE 3-8. Protection Dialog Box
- 3.3.6.6.3 Using Save and Recall [E-Series Models Only]
- FIGURE 3-9. Save/Recall Dialog Box
- 3.3.6.6.4 Resetting the Unit (*RST) [E-Series Models Only]
- FIGURE 3-10. Reset Dialog Box
- 3.3.6.6.5 Using a List (User-Programmed Sequences) [E-Series Models Only]
- FIGURE 3-11. List Dialog Box
- FIGURE 3-12. Adding Multiple Steps (Ramps) to List
- 3.3.6.6.6 Setting Limit Model [E-Series Models Only]
- FIGURE 3-13. Limit Model Dialog Box
- 3.4 Remote Programming Using Analog Signals
- 3.4.1 Programming with external resistance
- FIGURE 3-14. Analog Programming of Output Voltage or Current using Resistance
- 3.4.2 Programming with external Voltage
- FIGURE 3-15. Analog Programming of Output Voltage or Current using Voltage
- 3.4.3 Changing Overvoltage or Overcurrent Protection Values in Analog Programming Mode
- SECTION 4 - CALIBRATION
- 4.1 General
- 4.2 Equipment Required
- 4.3 Calibration Using Front Panel Controls in Local Mode
- FIGURE 4-1. Analog Port Wiring for Calibration
- 4.3.1 Voltage Calibration (Local)
- 4.3.2 Current Calibration (Local)
- 4.3.3 External Calibration (Local)
- 4.3.4 Calibration Exit (Local)
- 4.4 Calibration using VXI plug&play Driver
- FIGURE 4-2. Calibration Window
- 4.4.1 Voltage Calibration (VXI plug&play Driver Demo)
- FIGURE 4-3. Voltage Calibration Window
- 4.4.2 Current Calibration (VXI plug&play Demo)
- FIGURE 4-4. Current Calibration Window
- 4.4.3 Analog Reference Calibration (VXI plug&play Demo)
- FIGURE 4-5. Analog Reference Calibration Window
- 4.4.4 Calibration Exit (VXI plug&play Demo)
- 4.5 Changing the Calibration Password
- Table 4-1. Factory Default Unit Passwords
- 4.6 Restoring Prior Calibration Values
- KLR Installation/Operation Summary