FIGURE 3-1. FUNCTION SWITCH MENU STRUCTURE

4. To change the preference, tap DC OUTPUT switch once. The status display changes to

ADJ? and the DC VOLTS display starts to blink. Rotate either the VOLTAGE or CURRENT
control to alternate between C--F and F--C.

5. Tap DC OUTPUT switch to accept new preference. status display briefly shows WAIT, then

changes to ADJ and DC VOLTS display stops blinking. To exit rotate either the VOLTAGE or
CURRENT control until status display reads RTN and tap DC OUTPUT switch to return to
previous menu.

3.2.5

ENABLING/DISABLING OUTPUT POWER

When the power supply is turned on, the output is normally disabled (DC OUTPUT indicator is
off) and the DC VOLTS and DC AMPERES displays show the programmed output voltage and
current set points and the status display reads SET. However, if the unit has been set to AUTO
fault recovery, the output may be enabled when the unit is turned on (see PAR. 3.2.17.3.2).

To enable the output, first tap either VOLTAGE or CURRENT control once to exit setpoint mode
(SET disappears from the status display) then tap the DC OUTPUT switch once. The DC OUT-
PUT
indicator goes on to indicate the output is enabled.

FUNCTION––––––––LMT * (PAR. 3.2.9)

–––CNFG (PAR 3.2.16)––––VERS

–– MODL

–– Options

–– RTN

–––ADDR (PAR 3.2.12)
–––BAUD ***(PAR 3.2.13)
–––M/S *** (PAR 3.2.14)––– SERI ––––– 1OF2

––2OF2

–– PARA–––– 1OF2

––2OF2

–––LAN ** (PAR 3.2.15)–––––LRST

–––DHCP
–––[AUTO
–––MAC1/MAC2/MAC3
–––IP1/IP2
–––MSK1/MSK2
–––GTE1/GTE2
–––DNS1/DNS2
–––RTN

–––UTIL (PAR 3.2.17)––––––RELY (PAR 3.2.17.1)–––––FLT––––––––NORM

––– V->C

––– C->V

–––EXIT

––– RTN

––MAN

––LIST

––RTN

–––QkBt (PAR 3.2.17.2)
–––ADJ (PAR 3.2.4)
–––SYST (PAR 3.2.17.3)––––rINH *

* PASSWORD REQUIRED.

–––RCOV *–––––OVP

** E-SERIES MODELS ONLY.

––– OCP

*** STANDARD MODELS ONLY.

–––RTN

––– OLF

–––ANRB (PAR 3.2.17.4)

––– TEMP

–––ANPR (PAR 3.2.17.5)

––– PWR

–––LBT ***

––– RTN

–––CAL * (PAR 4.1)

–––RTN