beautypg.com

KEPCO KLR Series User Manual User Manual

Page 18

background image

1-6

KLR 091313

PROGRAMMING CHARACTERISTICS - ANALOG

Analog remote control

selection Activate with jumper at analog program-

ming connector

Recognized during power up.

isolation Safety Extra Low Voltage (SELV)

Analog Input Update Rate

2Hz (0.5 Second) Applies to program-
ming by voltage/ resistance and read-
back specifications.

Analog input voltage digitized (12-bit
resolution), optically isolated, then pro-
cessed by digital section.

Programming by voltage

voltage 0-10V

See PAR. 4.3.3 to reduce Full Scale
voltage.

current 0-10V

Min. programming limit; see Table 1-2.
See PAR. 4.3.3 to reduce Full Scale
voltage.

Programming by resistance

voltage 0-10K Ohms

See PAR. 4.3.3 to reduce Full Scale
resistance.

current 0-10K Ohms

Min. programming limit; see Table 1-2.
See PAR. 4.3.3 to reduce Full Scale
resistance.

Readback

0-10V proportional signal

Proportional to analog control volt-
age/resistance.

Remote inhibit

TTL compatible

Dual polarity; see PAR. 3.2.17.3.1.

Composite status flag

Isolated form C contacts

Programmable functions (PAR.
3.2.17.1).

PROGRAMMING CHARACTERISTICS - DIGITAL

Supported Interfaces

standard models GPIB and RS 232

SCPI command set for GPIB and RS
232 (see KLR Developer’s Guide).

E-Series models GPIB and LAN

Support SCPI command set (see KLR
Developer’s Guide) for GPIB and LAN;
Support four interfaces for LAN:
1. Web interface, port 80
2. SCPI Telnet, port 5024
3. SCPI Sockets, port 5025
4. VXI 11, port 1024

GPIB

GPIB address range: 1 to 30

Factory default is 6.

RS 232

standard models Baud Rate range: 2400, 4800, 9600,

19,200 or 38,400

Factory default is 38,400.

Digital remote control

isolation Safety Extra Low Voltage (SELV)

format compatible with SCPI protocols

W98 SE and later operating systems.

Programming resolution

0.024% of Emax and Imax

Programming accuracy

0.05% of Emax and Imax

Readback resolution

0.024% of Emax and Imax

Readback accuracy

0.1% of Emax and Imax

Status reporting

OVP, OCP, OTP, output lead fault
(OLF), fan failure, power loss

See PAR. 1.5.4 and 1.5.9.

TABLE 1-3. KLR SPECIFICATIONS (Continued)

SPECIFICATION

RATING/DESCRIPTION

CONDITION/COMMENT