beautypg.com

KEPCO KLR Series User Manual User Manual

Page 17

background image

KLR 091313

1-5

PHYSICAL CHARACTERISTICS

Dimensions

English

1.735”H x 19"W x 17.5"D

Depth excluding connectors and termi-
nal blocks (see Figure 1-2).

metric

44.45 x 482.6 x 443.7 mm

Weight

English

15 lbs

metric

6.82kg

Dielectric strength

Input - Chassis

2121V d-c

Output - Chassis

2121V d-c

(1250V d-c 20V and 40V models)

Input - Output

4242V d-c

(2500V d-c 20V and 40V models)

Source power connector

IEC 320-C19 appliance inlet

Load connections

20V and 40V

models

Nickel plated copper busbar with inte-
gral threaded stud (1/4-20-1/2in.)

Provision for safety covers.

75-300V models Shock-safe Euroblock, single conduc-

tor size: 20-10AWG (0,5 - 5,0 mm2)

Analog programming port.

15 pin D-sub

Digital programming ports

primary Standard GPIB connector

IEEE 488.2 (GPIB)

secondary 9 pin D-sub

RS 232 (standard Models only)

secondary RJ 45

LAN (E-Series Models Only)

Feedback/Control Input

5 position low profile Euroblocks

PROGRAMMING CHARACTERISTICS - LOCAL

Local control

rotary encoders

Panel mounted.

Local control resolution

Coarse ~100 LSB/step

Depress control for Fine resolution

Fine 1 LSB/step

Setting range

0-100% of rating

Power up settings

voltage defaults to zero

See PAR. 3.2.10.3 for Last Settings
Recall function.

current defaults to min. value (See Table 1-2)

Protection Limits

Overvoltage 20-120% of Emax

Programmable; accessed via front
panel protect switch or SCPI command
over digital bus.

Overcurrent 72-120% of Imax

TABLE 1-3. KLR SPECIFICATIONS (Continued)

SPECIFICATION

RATING/DESCRIPTION

CONDITION/COMMENT