beautypg.com

KEPCO JQE 150-1.5MVPY-26956 Half Rack User Manual

Page 33

background image

JQE SPECIAL SVC 081111

3-9/(3-10 Blank)

where

(I

lim B

)

e

= Current limit “B” determined by the external resistance connected to terminals

RPC1 and RPC2 of TB502.

(I

lim B

)

i

= Current limit “B” determined by the internal resistance only (with external resistance

disconnected).

R

cco

= 5 Ohms (tolerance ±1%) = the initial value of internal current control “B” for full

counterclockwise position.

R

cci

= the value of internal current control “B.” The current value of R

cci

can be measured

with the unit turned off, using a digital ohmmeter connected between terminals
RPC1 and RPC2 of rear barier strip TB502. The nominal value of R

cci

for fully clock-

wise position is 500 Ohms (tolerance ±5%).

R

cce

= the value of external resistance connected in parallel with internal current control

“B.”

NOTE: If R

cci

and R

cce

are much higher than R

cco

, the above equation can be simplified as:

Ilim B

(

)

e

Ilim B

(

)

i

Rcce

Rcci Rcce

+

-------------------------------

=