RISCO Group axesplus® User Manual
Page 47

User Manual for Hardware Installation
Uncontrolled when printed
© RISCO Group
46
8.5
LED Indications of PMC
PMC shows the indications as described in the following table.
Table 6: LED Indications
LED Type
Description
comm fail – RED
When communication between ACCB/Proxy and PMC fails, this
LED glows RED otherwise it remains OFF
aux fail – RED
When AUX1 and AUX2 fails, this LED glows RED else remains OFF
AC Fail – RED
When external power supply fails, this LED glows RED else remains
OFF
Bat Fail
When the Battery fails, this LED turns BLUE else remains OFF
PWR – GREEN
When the PMC board has any source of power supplied to it, it
glows GREEN, else turns OFF.
AUX1 PWR and AUX2 PWR –
GREEN
AUX1 and AUX2 when have any source of power to them, they
glow GREEN else are OFF