RISCO Group RP128EZ01 User Manual
Installation
-1-
Single Zone Expander
(RP128EZ01)
The RISCO RP128EZ01 is a Single Zone Expander that enables to connect any detector to RISCO system
BUS. Using the BUS connection you can ease your installation by connecting any detector in parallel
connections from any point along the wiring route. In addition you can define any detector with one of
the following zone terminations supported by the panel: NO, NC, EOL, DEOL, TEOL.
The following instructions explain how to connect to the RP128EZ01 the ProSYS.
Notes:
1. Up to 32 Single Zone Expanders can be installed on the ProSYS main BUS.
2. Up to 128 Single Zone Expanders can be assigned to the ProSYS using the BUS Zone Expander.
The following instructions explain how to connect a detector to the ProSYS BUS using the RP128EZ01.
Installation
1. Set the RP128EZ01 ID number (1-32) using DIP switches 1-5.
SW1 (1 - 5): ID switches. Defines the Single BUS Zone Expander ID number
SW1 - 6: Not used
ID
DIP - 1 DIP - 2
DIP - 3 DIP – 4 DIP - 5
ID
DIP - 1
DIP - 2
DIP - 3
DIP - 4
DIP - 5
1
Off
Off
Off
Off
Off
17
Off
Off
Off
Off
On
2
On
Off
Off
Off
Off
18
On
Off
Off
Off
On
3
Off
On
Off
Off
Off
19
Off
On
Off
Off
On
4
On
On
Off
Off
Off
20
On
On
Off
Off
On
5
Off
Off
On
Off
Off
21
Off
Off
On
Off
On
6
On
Off
On
Off
Off
22
On
Off
On
Off
On
7
Off
On
On
Off
Off
23
Off
On
On
Off
On
8
On
On
On
Off
Off
24
On
On
On
Off
On
9
Off
Off
Off
On
Off
25
Off
Off
Off
On
On
10
On
Off
Off
On
Off
26
On
Off
Off
On
On
11
Off
On
Off
On
Off
27
Off
On
Off
On
On
12
On
On
Off
On
Off
28
On
On
Off
On
On
13
Off
Off
On
On
Off
29
Off
Off
On
On
On
14
On
Off
On
On
Off
30
On
Off
On
On
On
15
Off
On
On
On
Off
31
Off
On
On
On
On
16
On
On
On
On
Off
32
On
On
On
On
On
2. Wire the RP128EZ01 BUS wires Red, Black (COM), Yellow(BUS) and Green (BUS) to the
ProSYS BUS.
Notes:
For maximum operation stability, it is best NOT to exceed a total of 300 meters (1000 feet) of wiring from the
ProSYS BZ1 to the ProSYS panel or to the BUS Zone Expander.
Wiring RP128EZ01 to the Main BUS