RISCO Group RP512EZ16 User Manual
Risco 16 zone expander

EN
RISCO 16 Zone Expander
(RP512EZ16)
The RISCO 16 Zone Expander enables to expand the number of wired zones in the ProSYS Plus.
DIP Switches Settings
Switch 1-5
Defines the Zone
Expander ID
number.
Switch 6-7
Not Applicable
Switch 8:
Tamper Bypass
Instead of a short
between the
TMP/COM
terminal block)
Zone Termination
Note:
:
The RP512EZ16 enables to define the end-of-line resistance of its zones. Selection is done via the panel keypad or
Configuration Software with the following available options
RTTE Compliance Statement:
Hereby, RISCO Group declares that this equipment is in compliance with the essential requirements and
other relevant provisions of Directive 1999/5/EC.
For the CE Declaration of Conformity please refer to our website: www.riscogroup.com.
No
EOL
DEOL
No
EOL
DEOL
No
EOL
DEOL
TEOL
0
Customized
5
3.74K 6.98K
10
3.3K
3.3K
1
2.2K
2.2K (Default) 6
2.7K
2.7K
11
5.6K
5.6K
2
4.7K
6.8K
7
4.7K
4.7K
12
2.2K
1.1K
3
6.8K
2.2K
8
3.3K
4.7K
13
2.2K
4.7K
4
10K
10K
9
1K
1K
14
4.7K
6.8K
12K
Technical Information
Current Consumption
20 mA typical, 100mA Maximum
Main Panel Connection
4-wire BUS, ≤300 m from Main Panel
Dimensions
16.5 cm x 6.6 cm x 1.8 cm