5.3
ACCB and ACIB Connection Diagram without PMC
The diagram below depicts connection of ACCB and ACIB without using a PMC.
Figure 9: ACCB ACIB connection without PMC
ACCB to ACIB Connection
The RAN BUS 3 has a Green (GRN) and Yellow (YEL) wire.
1. Connect the GRN of RAN BUS3 on ACCB to the GRN of ACIB.
2. Connect the YEL wire on ACCB and ACIB.
ACCB to AC/DC Converter
1. Connect the COM BLK of RAN BUS3 on ACCB to negative ground of AC/DC Converter.
2. Connect the positive power of AC/DC Converter to AUX RED on ACCB.