RISCO Group axesplus® User Manual
Page 15

User Manual for Hardware Installation
Uncontrolled when printed
© RISCO Group
14
Proxy to PMC
1. Connect the COM BLK of the RAN Bus 1 of Proxy to the COM2 BLK of the PMC as seen in the
Figure 3: Proxy connection with PMC.
2. Connect the PWR2 RED of AUX2 on the PMC to AUX RED of RAN BUS1 on Proxy.
3. Connect the Green (GRN) of the RAN BUS1 on Proxy to the GRN of RAN BUS on PMC.
4. Connect the Yellow (YEL) of the RAN BUS1 on Proxy to the YEL of RAN BUS on PMC as
shown.
Other Connections
1. Connect the positive of the battery (BAT.) of PMC to the positive of external Battery, ratings
12 V and 7 Ah.
2. Connect the negative of the battery (BAT.) of PMC to the negative of the external Battery.
3. Connect the Power Input Negative Black of PMC to the negative – ground of the AC/DC
converter.
4. Connect the positive power of the AC/DC converter to the Power Input Positive Red of
PMC.
4.3
Proxy Connection Diagram without PMC
Following diagram shows the connection of Proxy without using a PMC.