Precision Digital PD6310 User Manual
Page 40
Model PD6210 & PD6310 Batch Controllers
Instruction Manual
40
Display Parameter
Action/Setting
Description
mode
Batch mode
Automatic or manual batch control
T dly
Time delay
Set time delay for automatic batch restart
GT tb
Grand total time
base
Program grand total time base
GT CF
Grand total
conversion factor
Program grand total conversion factor
GT rst
Grand total reset
Program grand total reset mode: auto or
manual
dsplay
Display
Enter the Display menu
big
Upper display
Press Enter to assign the Upper display
parameter (default: PV or rate)
Little
Lower display
Press Enter to assign the Lower display
parameter (default: total)
d-Inty
Display
intensity
Set display intensity level from 1 to 8
RELaY
Relay
Enter the Relay menu
Assign
Assignment
Assign relays to rate, total (batch control),
grand total, or Modbus controlled.
Asign1
Assign 1
Relay 1-2 assignment
TotaL
Total
Assign relay to batch control
Gtotal
Grand total
Assign relay to grand total
mbus
Modbus
Assign relay to Modbus input
rate
Rate
Assign relay to rate
precls
Batch total relay
preclose
For relays beyond the first assigned to
total, a preclose amount may be entered.
RLY 1
Relay 1
Relay 1 setup
Act 1
Action 1
Set relay 1 action
1
Auto
Automatic
Set relay for automatic reset
A-man
Auto-manual
1
Set relay for automatic & manual reset
any time
1
(relays assigned to rate)
LatcH
Latching
1
Set relay for latching operation (relays
assigned to rate)
1
Lt-CLr
Latching-cleared
1
Set relay for latching operation with
manual reset only after alarm condition