beautypg.com

MCZ PowerBox COMPACT User Manual

Page 52

background image

Chapter 5

INSTALLATION AND USE MANUAL

page

52

Maintenance and cleaning

Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited

gaskets on the fire door. If necessary, contact an authorized service

centre to have them replaced

MCZ suggests relying on an authorized service centre

for end-of-season cleaning and maintenance, who

will carry out all of the previously mentioned work

and make a general check of the stove's components.

5.2.6.

Shutting the stove down (end of season)

At the end of season, we recommend completely removing pellets from

the hopper with the use of a vacuum cleaner with an extension.
In the period when the unit is out of use it must be

disconnected from the electricity mains. Upon re-start, when

pressing the main switch does not cause the control panel display to

light up, it could mean that the service fuse needs replacing.
On the main button there is a fuse box which is located above the

power socket. Use a screwdriver to open the fuse-holder compartment

and if necessary replace them (3.15 A delayed)

5.2.7.

Check of internal components

ATTENTION!
The check of the internal electro-mechanical

components must be carried out only by qualified

personnel with technical knowledge of electricity and

combustion.


We recommend that an annual maintenance service is carried out,

preferably under a programmed service contract. The essential part of

this service is a visual and functional check on the internal components:
The following is a summary of the checks and/or maintenance tasks

which are indispensable for the correct operation of the stove.

PARTS / INTERVAL

1 DAY

2-3 DAYS

30 DAYS

60-90 DAYS

1 YEAR

Grate

Ash collection

t

t

Ash drawer

Glass

Lower heat exchanger

Complete exchanger

Smoke duct

Door seal

Air filter

Flue pipe

Remote control battery