Making the electrical connections, Realization of cladding, Insulating a wooden beam – MCZ PowerBox COMPACT User Manual

Page 21: Installation of standard mcz cladding

background image

Chapter 3

INSTALLATION AND USE MANUAL

page

21

Installation and fitting

Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited

3.8. MAKING THE ELECTRICAL CONNECTIONS

Connect the power cord to the back of the product first. Then connect

it to an electrical wall socket that is always accessible.
. If this is not possible, during installation provide suitable devices for

disconnection from the power supply network, in compliance with

national standards on electrical systems.
Once the power cord has been connected, and all installation and

cladding is complete, place the switch in the position (I). The lighted

button will come on and also the LED of the emergency panel will come

on steady red.

When not in use it is advisable to unplug the power

cord.

3.9. REALIZATION OF CLADDING

The product must be fully tested before the cladding

is placed. MCZ shall not be held liable for any

damage to the cladding if abnormal operation occurs

that were not checked before cladding the unit.
You MUST check the seal of all tubes where smoke

passes (smoke connection, gaskets and insertion in

flue pipe) before cladding.

BEFORE YOU START CLADDING OF THE UNIT, READ

CHAPTER 5.2 “OPERATING TEST”

The fireplace stove and the parts of the cladding must be attached to

one another WITHOUT COMING INTO CONTACT WITH THE

STEEL STRUCTURE to prevent transmission of the heat to the marble

and/or stone, and to allow normal thermal dilation. Use care with wood

finsihes such as crossbeams or shelves.
We recommend making the hood liner in fire-resistant

plasterboard of 15/20 mm. thickness, with a self-supporting frame in

galvanised profile, so as not put weight on components of the cladding

(such as wooden beams and marble architraves) which do not have a

load-bearing structure and to make it easy to work in the event of

future anomalies and/or maintenance.
Dry install the fire bed of the cladding, leaving an aperture of 1 cm

between the fireplace stove and the fire bed to provide insulation.

3.10. INSULATING A WOODEN BEAM

The wood beam must be protected with adequate insulation from

heated parts to prevent the risk of fire or damage of the cladding.

3.11. INSTALLATION OF STANDARD MCZ CLADDING

For the installation of cladding specifically designed for the MCZ

PowerBox, the installer should refer to the use and installation manual

included with each specific cladding.

THERMAL PROTECTION OF CROSSBEAM

1. Insulation applied or to be applied.
2. Wood beam
3. Marble or other material

1

1
3

10

2