Activation /de-activation of eco-stop mode, Hot air ventilation – MCZ PowerBox COMPACT User Manual
Page 35

Chapter 4
INSTALLATION AND USE MANUAL
page
35
Operation
Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited
follow a pre-established ramp up to the 5
th
power. Once 20°C is
reached, it goes into standby mode. When the room temperature
drops below the value set on the remote control (for example
18°C) and a sufficient shutdown time has elapsed, the stove will
come back on automatically and continue running until again
reaching 20°C. If the temperature read by the sensor in the
remote control remains above the value set on the thermostat (for
example 20-21°C) the stove will remain off.
In this mode, lighting can be carried out by the user by resetting
the thermostat temperature to a value greater than that in the
room, or by shutting down the stove by pressing button 3 for a
few seconds and then pressing the same button to re-light the
stove.
The “ECO STOP” mode does not need to be reset as it remains in
memory from the last use.
4.9.4.1.
Activation /de-activation of ECO-STOP mode
This mode makes it possible to optimize stove consumption in well-
insulated rooms.
This operation can be selected whether your are in manual or
automatic mode by pressing and holding button 4 for 5 seconds.
The display of the remote control will show the message AUTO
along with the message ECOSTOP.
To disable the ECO-STOP function follow the same procedure.
4.10. HOT AIR VENTILATION
The Solar and Gea stove are equipped with an internal fan for
expulsion of heating air. It can be set to 5 different speeds at any
time regardless of the whether the stove is in manual or automatic
mode.
To access the fan setting menu, press the button MENU 6 once
and the icon for ventilation will come on completely. In fact,
normally only the border of the symbol appears, since to access
adjustment it is necessary to access the corresponding menu.
5 speeds can be selected as well as an automatic function.
To select the speed, after pressing button 6, press button 5 up or
down to increase or decrease ventilation power. Variation of
ventilation can be seen by the number of bars above the fan
symbol which will increase or decrease as a result.
In addition to 5th speed there is an additional selection called
AUTO function. This function lets you connect the fan speed to the
flame power. With this option selected, the stove will
independently select the fan speed based on the flame power.
This option can be selected simply by again pressing the up arrow
button of button 5 once you are at the 5th ventilation speed. The
display of the remote control will show the message AUTO under
the fan symbol.