Operation

Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited

follow a pre-established ramp up to the 5

th

power. Once 20°C is

reached, it goes into standby mode. When the room temperature

drops below the value set on the remote control (for example

18°C) and a sufficient shutdown time has elapsed, the stove will

come back on automatically and continue running until again

reaching 20°C. If the temperature read by the sensor in the

remote control remains above the value set on the thermostat (for

example 20-21°C) the stove will remain off.
In this mode, lighting can be carried out by the user by resetting

the thermostat temperature to a value greater than that in the

room, or by shutting down the stove by pressing button 3 for a

few seconds and then pressing the same button to re-light the

stove.
The “ECO STOP” mode does not need to be reset as it remains in

memory from the last use.

4.9.4.1.

Activation /de-activation of ECO-STOP mode

This mode makes it possible to optimize stove consumption in well-

insulated rooms.
This operation can be selected whether your are in manual or

automatic mode by pressing and holding button 4 for 5 seconds.
The display of the remote control will show the message AUTO

along with the message ECOSTOP.

To disable the ECO-STOP function follow the same procedure.

4.10. HOT AIR VENTILATION

The Solar and Gea stove are equipped with an internal fan for

expulsion of heating air. It can be set to 5 different speeds at any

time regardless of the whether the stove is in manual or automatic

mode.
To access the fan setting menu, press the button MENU 6 once

and the icon for ventilation will come on completely. In fact,

normally only the border of the symbol appears, since to access

adjustment it is necessary to access the corresponding menu.
5 speeds can be selected as well as an automatic function.
To select the speed, after pressing button 6, press button 5 up or

down to increase or decrease ventilation power. Variation of

ventilation can be seen by the number of bars above the fan

symbol which will increase or decrease as a result.
In addition to 5th speed there is an additional selection called

AUTO function. This function lets you connect the fan speed to the

flame power. With this option selected, the stove will

independently select the fan speed based on the flame power.

This option can be selected simply by again pressing the up arrow

button of button 5 once you are at the 5th ventilation speed. The

display of the remote control will show the message AUTO under

the fan symbol.