beautypg.com

Pellets – MCZ PowerBox COMPACT User Manual

Page 47

background image

Chapter 4

INSTALLATION AND USE MANUAL

page

47

Operation

Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited

MESSAGE ON

DISPLAY

TYPE OF PROBLEM

SOLUTION

A01

Fire fails to ignite

Check the level of pellets in the hopper.
Check that the grate is properly inserted in its housing
and does not have any obvious unburnt incrustations;
Check whether the ignition plug heats.

A02

Fire extinguishes abnormally

This is because the fire goes out due to lack of fuel
(hopper empty) or by an excess of pellets in the grate
which suffocates the flame.

A03

Pellet hopper temperature exceeds required
safety limit.
Overheating of the stove body

The air fan may be damaged or stopped, and is not able
to cool the structure. wait until the structure is cool
before restarting the stove.

A04

The temperature of the smoke discharge has
exceeded pre-set safety limits

The stove will shut off automatically. Let the stove cool
off for a few minutes, then re-light it.
Check smoke release and position of the temperature
probe.
Check the type of pellet being used.

A05

The pressure switch has tripped due to
obstruction of the flue pipe caused by foreign
objects, soot/ashes or atmospheric agents
(wind, snow, etc.)

Check and clean the WHOLE flue system
Protect the outlet from the wind.

A06

The smoke extractor is not able to provide the
primary air required for combustion.

Draught difficulties or clogging of grate.
Check whether the grate is clogged by incrustation and
clean as required.
Check and clean flue system as necessary

A07

During operation of the stove, superfluous air
is getting into the combustion chamber

Caused by prolonged opening of the fire door or by
substantial air infiltration (ash drawer missing or smoke
fan inspection plug missing)

A08

The smoke extractor is not running.

Check that the smoke fan compartment is clean and if it
is dirt that is blocking it.
Smoke fan failure. Replacement

A09

The smoke probe is defective and does not
properly measure the temperature of the
discharge smoke

Contact an authorized service centre to replace the
component.

A10

The plug is defective

Contact an authorized service centre to replace the
component.

A11

The reduction motor for feeding pellets to the
grate has failed

Contact an authorized service centre to replace the
component.

A12

The remote control has been beyond the
reception range of the stove for more than
three hours, or its batteries are dead.
NOTE: only in this case the stove does not go
into alarm shutdown, but continues operating
in the mode that the remote control set via
the last sent command.

Move the remote control back to within range of the
stove, or change the batteries if they are dead.
As soon as the stove receives a new signal from the
stove, the alarm indications will disappear. A easy way
to force a transmission to the stove is to press button 4.
This changes operating mode from manual to automatic
and vice versa.

A13

Generic failure of electronic control unit

Contact an authorized service centre to replace the
component.

A14

Generic failure of sensor

Contact an authorized service centre to replace the
component.

PELLETS

The pellet hopper sensor indicates that fuel is
running out

If you fill the hopper promptly during the pre-alarm, the
signal will disappear automatically after a few seconds.
If instead the unit has gone into alarm status due to
lack of pellets, fill the hopper, cancel the alarm and
restart.