Operation

Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited

When replacing the batteries, ensure correct polarity

by observing the symbols on the internal

compartment of the remote control.

4.6. EMERGENCY PANEL

On the front part of the Powerbox, the emergency panel is installed. It

was designed to diagnose any operating anomalies, and also to control

the PowerSystem if the remote control is not working.














KEY

A. Three figure display which indicates a series of information

about the stove, as well as the identification code for any

operating anomaly.

B. GREEN

LED to indicate:

OFF = Stove off

FLASHING = Stove in lighting phase

ON STEADY = Stove on

C. RED

LED to indicate:

OFF = Stove on

FLASHING SLOWLY = Stove shutting down

FLASHING RAPIDLY = Stove in alarm status

(accompanied for 10 minutes by a beep)

ON STEADY = Stove off

D. Three-position selector for function

OFF = Stove shut off manually in absence of remote

control

REMOTE = Stove can be controlled only by remote

control

ON = Stove turned on manually in absence of remote

control

E. Three-position selector for selection of power

MIN = Selector to run the stove at minimum power with

no remote control and with selector 4 in ON position

MED = Selector to run the stove at medium power with

no remote control and with selector

in ON position

MAX = Selector to run the stove at maximum power with

no remote control and with selector

in ON position

F. Push button for diagnostics of stove operating status
G. button to connect the stove to a new remote control (by means

of a procedure explained below)

TO OPERATE THE STOVE WITH THE REMOTE

CONTROL, SELECTOR "D" MUST BE PLACED

ON “REMOTE”

- OFF

- REMOTE

- ON

- MIN

- MED

- MAX

A

B

C

D

E

F

G

TEST