Maintenance and cleaning

Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited

5.2.3.

Cleaning of the heat exchanger

Halfway through the winter, but especially in the spring, you will

need to clean the air spaces where discharge smoke passes.
This cleaning must be done in order to remove all combustion residues

before time and humidity let them harden and make them difficult to

remove.

When the unit is cool, open the fire door and extract the ash drawer

and grate. Then loosen the three screws located just above the fire

mouth to remove the bracket that holds the internal Alutec refractory

parts. Gently remove the sides and then the back.

When removing the refractory parts, be careful not to

let them hit each other as they may chip or break. Put

them in a safe place until it is time to re-install them.

As soon as the refractory material back is removed, you will notice that

the steel back has openings where smoke normally passes. Insert a

bottle brush (preferable iron) in all of the openings and scrape the walls

of the fire box so that the ashes fall into the part below where the

inspection panels are located.
Loosen the bolts and open the inspection panels located under the ash

drawer. With a vacuum cleaner attachment, remove all the ash and

soot from the heat exchanger, again using a brush and the attachment.
Put everything back in place by performing the above steps in reverse

order.

5.2.4.

Cleaning of smoke duct and connection

When the unit is extracted, on the left it is possible to work on the

smoke intake volute (1) for cleaning and maintenance. To perform this

maintenance, you will need to remove the smoke intake fan.
On the outlet of the volute there is a gasket (3) that seals the

connection with the smoke connection (2). Always check the condition

of this gasket and replace it as needed. The gasket can also be

adjusted using a screw. You can turn the screw to increase or decrease

the pressure on the connection.
At the rear of the unit, at the volute outlet, there is the smoke

connection with its ash collection compartment (4). Also clean this

compartment with a vacuum cleaner, inserting the attachment in the

insertion hole of the volute.
Clean the smoke discharge system, especially in the area of the

connectors, curves and any horizontal stretches of pipe. For information

on cleaning the flue pipe, contact a professional chimney sweep.

WARNING:
The frequency with which the smoke discharge

system is cleaned should be determined based on the

type of use that is made of the product and the type

of installation.

5.2.5.

Other checks

All seal gaskets installed on components subject to maintenance

(smoke intake fan, inspection panels, etc.) must be replaced when

those parts are removed for maintenance. Check the seal of the

1. VoluteSmoke outlet and smoke

connectionSeal gasket between volute and

smoke connectionAsh collection

compartment

Screw for anchoring bracket that supports

Alutec refractory items

Cleaning and inspection panels

1

2

3

4