Introduction

Figure 1-2, Electrical Connection Points

9

10

8

7

12

11

Positive (+)

DC Terminal

(under cover)

Negative (–)

DC Terminal

(under cover)

Mounting

Flange

DC Equipment

Ground Terminal

AC Entry/

Exit

Connections

Intake Air Vents

(and on right front side)

7

DC Equipment Ground Terminal – this connection is used to tie the exposed chassis

of the inverter to the DC grounding system. This terminal accepts CU/AL conductors from

#14 to #2 AWG (2.1 to 33.6 mm

2

).

8

AC Entry/Exit Connections – two 3/4” knockouts provided with cable-clamp

strain

relief

s to accommodate and secure the AC input and output

fi eld

wiring.

9

Intake Air Vents ventilation openings to pull in air to keep the inverter cool for peak

performance.

10

Positive DC Terminal – provides a 360 degree connection point for the positive (+) cable

from the battery bank; consists of a 5/16-18 bolt with a Kep or Flange nut that holds the

battery cable to the DC terminal.

11

Negative DC Terminal – provides a 360 degree connection point for the negative (–)

cable from the battery bank; consists of a 5/16-18 bolt with a Kep or Flange nut that

holds the battery cable to the DC terminal.

12

Mounting Flange – used to secure the inverter to a shelf or wall.