Configuration and operation – KACO Powador 10.0 - 20.0 TL3 User Manual
Page 35

EN
Configuration and Operation
Operating Instructions Powador 12.0 TL3-20.0 TL3
Page 35
Country-
spec. Setting
Menu
level
Display/settings
Action in this menu/meaning
0
1
2
3
1
S0 pulse rate
"
Set the pulse rate of the S0 connection.
0
1
2
3
1
Powador-priwatt
"
Open the menu: Press the right arrow button or
the OK button.
0
1
2
3
2
Activation mode
"
Activate/deactivate Powador-priwatt function.
"
Select operating mode.
NOTE: Re-activation depends on the operating mode
selected and on the activation conditions.
0
1
2
3
2
Monitoring time
"
Set time span during which the power threshold
must be exceeded without interruption.
0
1
2
3
2
Power threshold
"
Set power threshold from which the monitoring
time up to activation begins.
0
1
2
3
2
Operation mode
"
Power-dependent: the function remains active until
below the set power threshold.
"
Time-dependent: The function is active depending
on the sunlight for the set operating time.
0
1
2
3
2
Operation time
NOTE: The menu option is only available in the “Time-
dependent” operation mode.
"
After connection, the function is active for the set
operating time.
0
1
2
3
1
Quick start
"
Reduce the waiting times during the self test by
pressing the “Activate” key.
0
1
2
3
1
Logging interval
"
Set the time interval between two log data
recordings.
0
1
2
3
1
Log data backup
The inverter supports the backing up of all recorded
yield data to a connected USB storage device.
"
Activate or deactivate log data backup.
0
1
2
3
1
Display
"
Configure the contrast setting for the display.
"
Set the length of time without user input after
which the backlighting of the LCD switches off.
"
Alternatively: Permanently activate or deactivate
the backlighting by selecting “On” or “Off”.
0
1
2
3
1
Date & time
"
Set the date and time.
NOTE: For self-diagnostic purposes, the inverter carries
out a daily restart at midnight. To avoid having a restart
occur during feed-in operation and to always obtain
reliable log data, ensure that the time is correctly set.