Mounting the inverter
Page 14
Operating Instructions Powador 12.0 TL3-20.0 TL3
NOTE
Power reduction due to heat accumulation.
If the recommended minimum clearances are not observed, the inverter can go into power regulation
mode or protective shutdown due to insufficient ventilation and the resulting heat buildup.
›
Maintain minimum clearances.
›
Ensure sufficient heat dissipation.
<20°
Figure 4: Instructions for wall mounting
CAUTION
Use suitable mounting parts.
›
Use only the supplied mounting parts.
›
Mount the inverter upright on a vertical wall only.
›
For a free-standing mounting an incline of 20° is allowed.
1386
405
260
565
1120
328
B
B
C
C
A
A
A
1
2
3
4
5
Figure 5: Minimum clearances/mounting plate