2 mechanical data, 3 software, Mechanical data – KACO Powador 10.0 - 20.0 TL3 User Manual
Page 11

EN
Technical Data
Operating Instructions Powador 12.0 TL3-20.0 TL3
Page 11
4.2
Mechanical data
12.0 TL3
14.0 TL3
18.0 TL3
20.0 TL3
Display
Graphical LCD, 3 LEDs
Controls
4-way button, 2 buttons
Interfaces
Ethernet, USB, RS485, S0
Fault signal relay
Potential-free NO contact, 230 V/1 A
AC connections: PCB terminal
PCB terminals inside the unit (max. cross section: 16 mm² flex-
ible, 10 mm² rigid)
AC connections: Cable connection
Cable connection via M40 cable fitting
DC connections
8 (2 x 4) MC-4-compatible plug connections
Ethernet connection: Cable connection
Cable connection via M25 cable fitting
Ambient temperature range [°C]
–25 ... +60, derating from +40
–25 ... +60,
derating
from +35
Humidity range (non-condensing) [%]
0 ... 95
Maximum installation elevation [m above sea level]
2,000
Temperature monitoring
yes
Cooling (free convection (K)/fan (L))
L
Protection rating according to EN 60529
IP65
Degree of contamination
2
Noise emission [dB(A)]
< 52/noiseless without fan operation
DC isolator switch
Built-in
Housing
Cast aluminium
H x W x D [mm]
Approx. 690 x 420 x 200
Total weight [kg]
40
40
44
44
Table 1:
Mechanical data
4.3
Software