background image

Determining the Antenna Locations

1-8 Site Preparation

Additional Location Requirements

This section describes other requirements to meet before installing the RoamAbout outdoor 
antennas. 

Lightning Protection

A lightning rod must be placed close to the antenna mast or wall bracket. This is required to 
protect the antenna from direct lightning strikes.

Grounding System

Direct earth grounding of the antenna and the Lightning Protector is necessary to protect the 
installation from lightning and the build‐up of static electricity. The wireless device and the 
Lightning Protector must be connected to the same earth ground using separate grounds. The 
antenna and the mounting structure require separate grounds to the same earth ground, using 
an equipotential bonding conductor. Check with a certified antenna installer, or local 
electrician, to make sure the antenna is properly grounded.

Ensure that the cable between the antenna and Lightning Protector is at least 0.9 meters 
(3 feet) away from high‐voltage or high‐current cable.

Antenna Height

If you are mounting the antenna on a roof, it must be at least 1.5 meters (5 feet) above the roof 
line.

If you are mounting the directional antenna to a wall of a building, it must be high enough to 
achieve a clear line of sight. Mounting an omni‐directional antenna to the side of a building 
can cause signal reflection and reduce distance.

AP placement

The AP should be located indoors, and connected to the outdoor antenna using the shortest 
cable possible to reduce the loss of the cable.