Ambient temperature, Main circuit terminal wiring – Yaskawa U1000 Industrial MATRIX Drive User Manual
Page 83

n
Ambient Temperature
IP20/NEMA Type 1 Enclosure: -10 to +40 °C
IP00 Open Type Enclosure: -10 to +50 °C
n
Main Circuit Terminal Wiring
Yaskawa recommends using closed-loop crimp terminals on all drive models. Use only the tools recommended by the terminal
manufacturer for crimping.
Refer to Closed-Loop Crimp Terminal Recommendations on page 83
terminal recommendations.
Wire Gauges and Tightening Torques
Refer to Main Circuit Wire Gauges and Tightening Torque on page 24
.
Closed-Loop Crimp Terminal Recommendations
To maintain UL/cUL approval, UL Listed closed-loop crimp terminals are specifically required when wiring the drive main
circuit terminals on models 2o0068 to 2o0248 and 4o0052 to 4o0414. Use only the tools recommended by the terminal
manufacturer for crimping. Yaskawa recommends UL Listed crimp terminals made by JST and Tokyo DIP (or equivalent)
matches the wire gauges and terminal screw sizes with Yaskawa-recommended crimp
terminals, tools, and insulation caps. Refer to the appropriate Wire Gauge and Torque Specifications table for the wire gauge
and screw size for your drive model. Place orders with a Yaskawa representative or the Yaskawa sales department.
Wire gauge values shown in bold italic are the recommended values. Refer to local codes for proper selections.
Table i.28 Closed-Loop Crimp Terminal Size
Drive Model
Wire Gauge
(AWG, kcmil)
Screw
Size
Crimp Terminal
Model Number
Tool
Insulation Cap
Model No.
Code
<1>
R/L1, S/L2, T/L3
U/T1, V/T2, W/T3
Machine No.
Die Jaw
200 V Class
2o0028
10
M5
R5.5-5
YA-4
AD-900
TP-005
100-054-030
8
R8-5
AD-901
TP-008
100-054-032
2o0042
8
M6
R8-6
YA-4
AD-901
TP-008
100-065-184
6
R14-6
AD-902
TP-014
100-051-261
4
R22-6
YA-5
AD-953
TP-022
100-051-262
3
R22-6
2o0054
6
M6
R14-6
YA-5
AD-952
TP-014
100-051-261
4
R22-6
AD-953
TP-022
100-051-262
3
2o0068
4
M6
R22-6
YA-5
AD-953
TP-022
100-051-262
3
2o0081
6
M6
R14-6
YA-5
AD-952
TP-014
100-051-261
4
R22-6
AD-953
TP-022
100-051-262
3
2o0104
6
M8
R14-8
YA-4
AD-902
TP-014
100-054-035
4
R22-8
YA-5
AD-953
TP-022
100-051-263
3
2
R38-8
AD-954
TP-038
100-051-264
1
1/0
R60-8
AD-955
TP-060
100-051-265
2o0130
6
M8
R14-8
YA-5
AD-952
TP-014
100-054-035
4
R22-8
AD-953
TP-022
100-051-263
3
2
R38-8
AD-954
TP-038
100-051-264
1
1/0
R60-8
AD-955
TP-060
100-0051-265
i.9 Standards Compliance
YASKAWA ELECTRIC TOEP C710636 04C U1000 Industrial MATRIX Drive Quick Start Guide
83