i.5

Start-Up Programming and Operation

u

Digital Operator Keys and Displays

LO

RE

F2

F1

ESC

RUN

STOP

ENTER

RESET

ALM

DIGITAL OPERATOR

12

11

9
8

1

2

3

10

4

5 6

7

Figure i.30 Keys and Displays on the Digital Operator

No.

Display

Name

Function

1

F1

F2

Function Key

(F1, F2)

The functions assigned to F1 and F2 vary depending on the currently displayed menu. The

name of each function appears in the lower half of the display window.

2

ESC

ESC Key

• Returns to the previous display.
• Moves the cursor one space to the left.
• Pressing and holding this button will return to the Frequency Reference display.

3

RESET Key

• Moves the cursor to the right.
• Resets the drive to clear a fault situation.

4

RUN

RUN Key

Starts the drive in LOCAL mode.

5

Up Arrow Key

Scrolls up to display the next item, selects parameter numbers, and increments setting

values.

6

Down Arrow Key

Scrolls down to display the previous item, selects parameter numbers, and decrements

setting values.

7

STOP

STOP Key

<1>

Stops drive operation.

8

ENTER Key

• Enters parameter values and settings.
• Selects a menu item to move between displays

9

LO/RE Selection Key

<2>

Switches drive control between the operator (LOCAL) and an external source (REMOTE)

for the Run command and frequency reference.

10

RUN Light

Lit while the drive is operating the motor.

11

LO/RE Light

Lit while the operator is selected to run the drive (LOCAL mode).

12

ALM LED Light

Lit when the drive detects an alarm or error.

<1> The STOP key has highest priority. Pressing the STOP key will always cause the drive to stop the motor, even if a Run command is active at any

external Run command source. To disable the STOP key priority, set parameter o2-02 to 0.

<2> The LO/RE key can only switch between LOCAL and REMOTE when the drive is stopped. To disable the LO/RE key to prohibit switching between

LOCAL and REMOTE, set parameter o2-01 to 0.

i.5 Start-Up Programming and Operation

YASKAWA ELECTRIC TOEP C710636 04C U1000 Industrial MATRIX Drive Quick Start Guide

43