beautypg.com

Yaskawa U1000 Industrial MATRIX Drive User Manual

Page 65

background image

No.

Checklist

Page

30

If an analog input supplies the frequency reference, make sure it produces the desired frequency reference. Make the

following adjustments if the drive does not operate as expected:

Gain adjustment: Set the maximum voltage/current signal and adjust the analog input gain (H3-03 for A1, H3-11 for A2,

H3-07 for A3) until the frequency reference value reaches the desired value.

Bias adjustment: Set the minimum voltage/current signal and adjust the analog input bias (H3-04 for A1, H3-12 for A2,

H3-08 for A3) until the frequency reference value reaches the desired minimum value.

i.5 Start-Up Programming and Operation

YASKAWA ELECTRIC TOEP C710636 04C U1000 Industrial MATRIX Drive Quick Start Guide

65