Drive, I.4 electrical installation – Yaskawa U1000 Industrial MATRIX Drive User Manual

Page 21

background image

+

+

-

+

+

+

-

+

+

S

1

S

2

S

3

S

4

S

5

S

6

S

7

MP

DM

DM

RP

A

1

A

2

A

3

0

V

AC

R
R
S
S-

IG

H

1

H

2

HC

Drive

2

k

S

8

SC

0

V

0

V

AC

FM

AM
AC

E (G)

S

1

S

2

<14>

<8>

<15>

<12>

<9>

<11>

<8>

<5>

<3>

+

24

V

+

V

MA

M

1

M

2

MB
MC

Forward Run / Stop

Reverse Run / Stop

External fault

Fault reset

Multi-speed step 1

Multi-speed step 2

External Baseblock

Jog speed

Multi-function

digtial inputs

(default setting)

Sink / Source mode

selection wire link

(default: Sink)

CN5-C

CN5-B

CN5-A

Option board

Pulse Train Input
(max 32 kHz)

Shield ground
terminal

Multi-function

analog/pulse

train inputs

Power supply +10.5 Vdc, max. 20 mA

Analog Input 1 (Frequency Reference Bias)
0 to +/-10Vdc (20 kΩ)
4 to 20 mA (250 Ω) / 0 to 20 mA (250 Ω)
Analog Input 2 (Frequency Reference Bias)
0 to +10Vdc (20 kΩ)
4 to 20 mA (250 Ω) / 0 to 20 mA (250 Ω)

Analog Input 3 (Aux. Frequency Reference)
0 to +/-10Vdc (20 kΩ)
4 to 20 mA (250 Ω) / 0 to 20 mA (250 Ω)

-

V

Power supply, -10.5 Vdc, max. 20 mA

Safety

switch

MEMOBUS/Modbus comm.

RS-422/RS-485

max. 115.2 kbps

Safe Disable inputs

Wire

jumper

Open

Safety relay /

controller

Termination resistor

(120 , 1/2 W)

DIP

Switch S2

Fault relay output

250 Vac, max. 1 A

30 Vdc, max 1 A

(min. 5 Vdc, 10 mA)

Multi-function relay output (During Run)

250 Vac, max. 1 A

30 Vdc, max 1 A

(min. 5 Vdc, 10 mA)

Multi-function pulse train output

(Output frequency)

0 to 32 kHz (2.2 k )

Multi-function analog output 1
(Output frequency)

-10 to +10 Vdc (2mA)
or 4 to 20 mA

EDM (Safety Electronic Device Monitor)

Main Circuit

Control Circuit

shielded line

twisted-pair shielded line

main circuit terminal

control circuit terminal

R/L1
S/L2
T/L3

M

3

M

4

Multi-function relay output (Zero Speed)

250 Vac, max. 1 A

30 Vdc, max 1 A

(min. 5 Vdc, 10 mA)

M

5

M

6

Multi-function relay output (Speed Agree 1)

250 Vac, max. 1 A

30 Vdc, max 1 A

(min. 5 Vdc, 10 mA)

SP

SN

<10>

AM

FM

V

I

V

I

DIP Switch S1

A2 Volt/Curr. Sel

DIP Switch S4

A3 Analog/PTC

Input Sel

PTC

AI

Off

On

DIP Switch S2

Term. Res. On/Off

Jumper S3
H1, H2
Sink/Source Sel.

Jumper S5

AM/FM Volt./Curr.

Selection

Terminal board

jumpers and switches

FM

+

AM

<6>

<13>

<12>

Multi-function analog output 2
(Output current)

-10 to +10 Vdc (2mA)
or 4 to 20 mA

Fuse

A+
A-

B-

Z-

B+

Z+

a+
a-
b+
b-
z+
z-

FE

IP
IG

TB1

SD

TB2

B track monitor

A track monitor

M

U/T

1

V/T

2

W/T

U
V

W

3

Ground

PG

PG- X3

connectors

(option)

Slide Switch S6

DM+, DM-

N.C./N.O. Selection

N.C.

N.O.

<7>

p1

n1

Terminals p1, n1 are for connection
options. Never connect power supply
lines to these terminals.

<1>

<2>

<4>

Cooling fan

M

FU
FV

FW

GFCI (MCCB)

R

T

S

Three-phase
power supply
240 to 500 V
50/60 Hz
(Depending on
model capacity)

2MCCB

r1

s1

t1

MC

Wiring sequence should shut off
power to the drive when a fault
output is triggered.

ON
OFF

EMC filter

Switch

<16>

24

0

FE

24 V

0 V

24 V Power Supply
Terminals

<17>

Figure i.12 Drive Standard Connection Diagram (example: model 2o0028)

i.4 Electrical Installation

YASKAWA ELECTRIC TOEP C710636 04C U1000 Industrial MATRIX Drive Quick Start Guide

21