2 general data, General data – SMA STP 15000TL Installation User Manual
Page 89

SMA Solar Technology AG
Technical Data
Installation Manual
STP20TLHE-IA-IEN122222
89
* Depending on country setting
Efficiency
13.2 General Data
* optional
Rated power frequency
50 Hz
AC power frequency*
50 Hz/60 Hz
Operating range at AC power frequency 50 Hz
44 Hz … 55 Hz
Operating range at AC power frequency 60 Hz
54 Hz … 65 Hz
Displacement power factor, adjustable
0.8
overexcited
… 0.8
underexcited
Feed-in phases
3
Connection phases
3
Overvoltage category as per IEC 60664-1
III
Maximum efficiency, η
max
99.0%
European weighted efficiency, η
EU
98.7%
Width x height x depth, with handle of DC switch-
disconnector*
665 mm x 680 mm x 265 mm
Weight
45 kg
Length x width x height of packaging
780 mm x 380 mm x 790 mm
Transport weight
53 kg
Climatic category (according to IEC 60721-3-4)
4K4H
Operating temperature range
− 25°C … +60°C
Maximum permissible value for relative humidity, non-
condensing
100%
Maximum operating altitude above Mean Sea Level
3,000 m
Noise emission (typical)
≤ 40 dB(A)
Power loss in night operation
< 1 W
Topology
Transformerless
Cooling concept
OptiCool: temperature-controlled fan
Fan connection
Designed for safe disconnection in
accordance with DIN EN 62109-1
Protection rating according to IEC 60529
IP65
Protection class (according to IEC 62103)
I
Strain relief category of the cable glands according to
EN 50262
A