beautypg.com

SMA STP 15000TL Installation User Manual

Page 72

background image

Messages

SMA Solar Technology AG

72

STP20TLHE-IA-IEN122222

Installation Manual

3801

< DC overcurrent >
< Check generator >
On the DC side of the inverter, an
overcurrent has been detected and the
inverter has briefly interrupted feed-in.

If this event occurs frequently:

• Check the design and the circuitry of

the PV array.

3901 …
3902

< Waiting for DC start conditions >
< Start cond. not met >
The input power or input voltage of the
PV modules is insufficient for feeding into
the electricity grid.

• Wait for more irradiation.
• If necessary, increase the voltage limit

for the start of feed-in if the event occurs
frequently in the morning (parameter
setting via communication).

• If this event recurs at medium

irradiation, check the PV plant design
and correct the circuitry of the PV array.

6001 …
6438

< Self diagnosis > or
< Interference device >

• Contact the SMA Service Line

(see Section 15 "Contact" (page 94)).

6501 …
6511

< Self diagnosis > or
< Overtemperature >
The inverter switches off due to excessive
temperature.

• Ensure sufficient ventilation.
• Check heat dissipation, as described in

Section 9.2 "Checking Heat
Dissipation" (page 61).

6603 …
6604

< Self diagnosis > or
< Overload >

• Contact the SMA Service Line

(see Section 15 "Contact" (page 94)).

6701 …
6702

< Comm. disturbed >
A fault has occurred in the internal
communication of the inverter. However,
the inverter continues feeding into the
grid.

If this event occurs frequently:

• Contact the SMA Service Line

(see Section 15 "Contact" (page 94)).

6801 …
6802

< Self diagnosis > or
< Input A defective >

• Contact the SMA Service Line
• (see Section 15 "Contact" (page 94)).

7001 …
7002

< Sensor fault fan permanently on >

• Contact the SMA Service Line

(see Section 15 "Contact" (page 94)).

7008

< Disturbance sensor display
temperature >

• Contact the SMA Service Line

(see Section 15 "Contact" (page 94)).

7101

< SD card defective >

Re-format the SD card.

• Re-save the files to the SD card.

7102

< Parameter file not found or defective > • Copy the parameter file into the

SD card drive :\PARASET directory.

Event no. Display message and cause

Corrective measures

This manual is related to the following products: