beautypg.com

4 connecting the pv array (dc), 1 conditions for dc connection, Connecting the pv array (dc) – SMA STP 15000TL Installation User Manual

Page 34: Conditions for dc connection

background image

Electrical Connection

SMA Solar Technology AG

34

STP20TLHE-IA-IEN122222

Installation Manual

6.4 Connecting the PV Array (DC)

6.4.1 Conditions for DC Connection

The inverter has 2 input areas, "A" and "B", each with its own reverse current protection. In total, up
to 6 strings can be connected.

• Requirements for the PV modules of the connected strings:

– Same type
– Same quantity of PV modules connected in series
– Identical alignment
– Identical tilt

• The connecting cables of the PV modules must be equipped with connectors. The DC connectors

for DC connection are included in the scope of delivery.

Use of Y adaptors
Y adaptors must not be visible or freely accessible in close proximity to the inverter.

• The DC electric circuit must not be interrupted by Y adaptors.
• Observe the procedure for disconnecting the inverter as described in

Section 8 "Disconnecting the Inverter from Voltage Sources" (page 58).