12 decommissioning, 1 dismantling the inverter, Decommissioning – SMA STP 15000TL Installation User Manual
Page 81: Dismantling the inverter

SMA Solar Technology AG
Decommissioning
Installation Manual
STP20TLHE-IA-IEN122222
81
12 Decommissioning
12.1 Dismantling the Inverter
1. Disconnect the inverter as described in Section 8 "Disconnecting the Inverter from Voltage
2. Release and disconnect all DC connectors.
To do this, insert a flat-blade screwdriver
(blade width: 3.5 mm) into one of the side slots and
pull the DC connectors straight out.
Do NOT PULL ON THE CABLE.
☑ All DC connectors are now disconnected from
the inverter. The inverter is entirely disconnected
from the PV array.
3. If connected, remove all communication cables from the inverter.
4. Screw off all projecting cable glands.
5. If necessary, open the anti-theft lock.
6. Remove the inverter from the back panel and remove the back panel from the mounting surface.
CAUTION!
Risk of burns due to hot enclosure parts
• Wait 30 minutes for the enclosure to cool down before disassembling.
+
+
A1
A2
A3
B1
B2
B3