SMA STP 15000TL Installation User Manual
Page 73
SMA Solar Technology AG
Messages
Installation Manual
STP20TLHE-IA-IEN122222
73
7105
< Param. setting failed >
• Check the parameters of the SD card
for valid values.
• Ensure change rights via SMA Grid
Guard code.
7106
< Update file defect. >
• Re-format the SD card.
• Re-save the files to the SD card.
7110
< No update file found >
• Copy the update file into the SD card
drive :\UPDATE directory.
7201 …
7202
< Data stor. not poss. >
An internal device fault that does not
prevent the inverter from feeding power
to the grid.
• If this fault occurs often, contact the
SMA Service Line (see Section 15
"Contact" (page 94)).
7303
< Update main CPU failed >
Internal device fault.
• Contact the SMA Service Line
(see Section 15 "Contact" (page 94)).
7305
< Update RS485I module failed >
An internal device fault that does not
prevent the inverter from feeding power
to the grid.
• Re-try update.
• If this fault occurs again, contact the
SMA Service Line (see Section 15
"Contact" (page 94)).
7307
< Update Bluetooth failed >
An internal device fault that does not
prevent the inverter from feeding power
to the grid.
• Re-try update.
• If this fault occurs again, contact the
SMA Service Line (see Section 15
"Contact" (page 94)).
7311
< Update language table failed >
An internal device fault that does not
prevent the inverter from feeding power
to the grid.
• Re-try update.
• If this fault occurs again, contact the
SMA Service Line (see Section 15
"Contact" (page 94)).
7401
< Varistor defective >
At least one of the thermally monitored
varistors is defective.
• Check the varistors as described in
Section 11.2 "Checking the Function of
the Varistors" (page 77).
7702 …
7703
< Self diagnosis > or
< Interference device >
• Contact the SMA Service Line
(see Section 15 "Contact" (page 94)).
8001
< Derating occurred >
The power supplied by the inverter has
been reduced to below the nominal
power for more than 10 minutes due to
excessive temperature.
If this event occurs frequently:
• Ensure sufficient ventilation.
• Check heat dissipation, as described in
Section 9.2 "Checking Heat
Dissipation" (page 61).
Event no. Display message and cause
Corrective measures