beautypg.com

SMA SUNNY HOME MANAGER Installation User Manual

Page 69

background image

SMA Solar Technology AG

11  Technical Data

Installation Manual

HoMan-IA-en-17

69

Ambient Conditions during Operation
Ambient temperature*

* When using the Sunny Home Manager at temperatures below 0°C and exceeding 40°C: do not use the supplied plug-in

power supply (see Section 11.3 "Plug-In Power Supplies", page 71). Requirements for the plug-in power supply: 12 V DC,
nominal current: 1.5 A.

− 25°C to +60°C

Relative humidity**

** non-condensing

5% to 95%

Degree of protection***

*** in accordance with IEC 60529

IP20

Maximum altitude above MSL (Mean Sea Level)

2,000 m

Communication Interface to Other Devices
SMA devices

BLUETOOTH, Speedwire

Devices controlled via a data exchange protocol

Ethernet

Computer

Ethernet

Sunny Portal

Ethernet

Maximum Range
BLUETOOTH*

* maximum range in free-field conditions

100 m

Ethernet

100 m

Internal Memory
Cache for PV system data

5 days

Number of Devices
Maximum number of SMA devices

16

Maximum number of SMA inverters

12

Maximum number of SMA radio-controlled
sockets

10

Maximum number of devices controlled via a
data exchange protocol

32