11  Technical Data

SMA Solar Technology AG

68

HoMan-IA-en-17

Installation Manual

11 Technical Data

11.1 Sunny Home Manager

General Data
Status display

LEDs

Maximum length of cables to energy meters with
S0 interface

30 m

Maximum length of cables to energy meters with
D0 interface

15 m

Certified countries

Australia, Belgium, Germany, France, Italy,

Greece, Great Britain, Canada, Luxembourg,

Portugal, Spain, Czech Republic, Austria,

Switzerland, USA

Mechanical Data
Width x height x depth

170 mm x 124.5 mm x 41.5 mm

Weight

220 g

Voltage Supply
Voltage supply

Plug-in power supply, top-hat rail power supply

DC input voltage

12 V

Maximum typical power consumption

6 W

Maximum power consumption

14.3 W

Terminals
Speedwire/Ethernet*

* Data transfer rate 10 Mbit per second or 100 Mbit per second

RJ45

Number of 2 x 4-pole pin connectors for
energy meters

3

Number of USB pin connectors**

** Currently without function

2