6 Installation
6.1 Requirements for the Mounting Location of the
Sunny Home Manager
☐ The mounting location must be indoors.
☐ The mounting location must be protected against dust, moisture and corrosive substances.
☐ The cable route from the mounting location to the router must not exceed a maximum length of
100 m.
☐ The cable route from the mounting location of the Sunny Home Manager to the energy meters
with D0 interface must not exceed a maximum length of 15 m.
☐ The cable route from the mounting location of the Sunny Home Manager to the energy meters
with S0 interface must not exceed a maximum length of 30 m.
☐ A minimum distance of of 1 m must be maintained from devices using the 2.4 GHz radio
spectrum (e.g. WLAN devices, microwave ovens). This will prevent reduced connection quality
and data transmission speed.
☐ The Sunny Home Manager must not have radio shielding (e.g. in a metal cabinet).
Minimum Clearances:
Figure 11: Minimum clearances
• Observe minimum clearances to walls, other communication products, inverters, or objects.
6.2 Requirements for the Mounting Location of the
SMA Radio-Controlled Socket
☐ The SMA radio-controlled socket must only be operated in wall outlets that are suitable for the
power of the connected load.
☐ A minimum distance of of 1 m must be maintained from devices using the 2.4 GHz radio
spectrum (e.g. WLAN devices, microwave ovens). This will prevent reduced connection quality
and data transmission speed.
SUNNY HOME MANAGER
70 mm
70 mm
150 mm
50 mm