9  Troubleshooting

Operating Manual

SC-COM-BE-en-20

37

9 Troubleshooting

9.1 Error Overview

Problem

Cause and corrective measures

The user interface cannot be

reached.

The network connection of the SC-COM has been interrupted.

Corrective measures:

• Make sure all network cables of the SC-COM and the computer are

connected properly.

The network settings of the computer do not match the network settings of the

SC-COM.

Corrective measures:

• Make sure the router settings are correct.

Make sure the Internet browser settings are correct. Define a proxy server

exception if necessary.

• Contact your network administrator if you require assistance.

SC-COM does not detect devices

that are connected to the RS485

communication bus.

The data transmission protocol and the baud rate are not configured properly.

Corrective measures:

• Make sure the data transmission protocol and the baud rate for the

connected devices are configured properly.

• Make sure the RS485 cable is connected properly (refer to the RS485

cabling plan at www.SMA.de for information on how the cables should be

connected to the RS485 communication bus).

SC-COM does not transmit any

data to Sunny Portal.

Data transmission is disabled.

Corrective measures:

• Enable data transmission to the Sunny Portal (see Section 7.3.1 "Registering

the SC-COM in Sunny Portal", page 27).

• Make sure the plant name and e-mail address you entered are correct.

You may need to register again in the Sunny Portal.

After an FTP download, the

Internet Explorer shows old

SC-COM data.

The cache behaviour of the Internet Explorer means that an outdated version of

the data is loaded from the SC-COM.

Corrective measures:

• Use an FTP client such as FileZilla to load data from the internal FTP server

of the SC-COM.

The events in the event report do

not appear in the expected

location under "Time".

The time settings of the SC-COM and the connected device do not match.

Corrective measures:
Synchronise the time settings of the SC-COM and the connected device

(see the manual of the connected device).