beautypg.com

2 leds on the network terminal – SMA SC-COM User Manual

Page 12

background image

3  Product Description

SMA Solar Technology AG

12

SC-COM-BE-en-20

Operating Manual

3.3.2 LEDs on the Network Terminal

Figure 4: LEDs on the network terminal

H2

Flashing green

The SC-COM is communicating with the internally connected devices.

Glowing green

Internal communication has taken place in the last five minutes.

Glowing red

An error has occurred in the internal communication.

Off

No internal communication has taken place in the last five minutes.

H3

Flashing red

The SC-COM is starting up.

Glowing red

An error has occurred at the SC-COM.

Glowing green

The SC-COM is ready for operation.

H4

Glowing green

An internal memory card exists and it is less than 92% full.

Glowing red

The internal memory card is full and the oldest saved data is being

overwritten.

Flashing red

The internal memory card is 92% full.

H5

Glowing green

An external memory card exists and is less than 92% full.

Glowing red

The external memory card is full.

Flashing red

The external memory card is 92% full.

Off

There is no external memory card.

H6

Not assigned

H7

Not assigned

H8

Flashing green

Application is running.

Position

LED

Colour

Status

Explanation

A

Speed

Yellow

On

100 MBit data transfer rate

Off

10 MBit data transfer rate

B

Link /

Activity

Green

On

Connection (link) established

Flashing

The SC-COM is currently transmitting or receiving data

(activity).

Off

No connection established

LED designation

Status

Explanation