7.3 Setting Data Communication with Sunny Portal

7.3.1 Registering the SC-COM in Sunny Portal

1. Log in on the user interface.
2. Select Sunny Central > Settings > Data transmission.
3. Enter the name of your plant in the field Plant name. The name you enter will be displayed as the plant name in

Sunny Portal.

4. Setting the Data Transmission Frequency (see Section 7.2 "Setting the Data Transmission Frequency", page 26).
5. Select yes in the Use Sunny Portal field.

7. Enter your e-mail address in the Operator e-mail field. Sunny Portal sends your access data to this e-mail address.
8. Select the button [Save].
9. Select Sunny Central > Info.

10. Select [Register] in the field Last Sunny Portal registration. The Sunny Portal password will be sent to the

specified e-mail address.

7.3.2 Adjusting the Plant Identifier for Sunny Portal

Sunny Portal identifies your SC-COM via the plant identifier. In the following cases, you must adjust the plant identifier in

the SC-COM:

• Plant data has already been sent to Sunny Portal via another communication device.
• The plant identifier assigned to the SC-COM was reset.
• The SC-COM was replaced by a different SC-COM.

Procedure:

1. Log into Sunny Portal (www.SunnyPortal.com).
2. Select Configuration > Plant Properties.
3. Copy the plant identifier to the clipboard.
4. Log in on the user interface.
5. Select Sunny Central > Settings > Data transmission.
6. Delete the content of the Plant identifier field.
7. Paste the plant identifier from the clipboard into the Plant identifier field.
8. Select the button [Save].

7.3.3 Deleting the Sunny Portal Buffer

You can delete the data on the internal ring buffer.

1. Log into the user interface as an installer.
2. Select Sunny Central > Info.
3. Select [Delete] in the "Sunny Portal Buffer Load" field.

6.

Automatic plant identifier
In general, you do not have to change the preset number in the Plant identifier field. Sunny Portal uses this

number to uniquely identify your PV plant. If you have not yet registered the plant in Sunny Portal, the SC-COM

will automatically enter the preset plant identifier in Sunny Portal after the first successful data upload.

Sunny Portal will send the login data to the e-mail address you entered in the Operator e-mail field. The plant

is now registered in Sunny Portal.

• If the plant is already registered in Sunny Portal, update the plant identifier in the field Plant identifier

(see Section 7.3.2 "Adjusting the Plant Identifier for Sunny Portal", page 27).