background image

Manual operation and setup

15.9 Datum Setting with 3-D Touch Probe

15

502

TNC 640 | User's Manual for DIN/ISO Programming | 3/2014

Outside circle:

Position the touch probe at a position near the first touch point

outside of the circle
Select the probe direction by soft key
Probing: Press the machine START button. If you are not

using the automatic probing routine, you need to repeat this

procedure. After the third probing operation, you can have the

TNC calculate the center (four touch points are recommended).
Terminate the probing procedure and switch to the evaluation

menu: Press the EVALUATE soft key
Datum: Enter the coordinates of the datum and confirm your
entry with the

SET DATUM soft key, or write the values to a

table (See "Writing measured values from the touch probe

cycles in a datum table", page 488, or See "Writing measured

values from the touch probe cycles in the preset table",

page 489)
To terminate the probe function, press the

END soft key

After the probing procedure is completed, the TNC displays the

current coordinates of the circle center and the circle radius PR.

Setting the datum using multiple holes/cylindrical studs

A second soft-key row provides a soft key for using multiple holes

or cylindrical studs to set the datum. You can set the intersection of

two or more elements as datum.
Select the probing function for the intersection of holes/cylindrical

studs:

Select the touch probe function: Press the

PROBING CC soft key
Hole is to be probed automatically:

Define by soft key

Circular stud is to be probed automatically:

Define by soft key

Preposition the touch probe approximately in the center of the hole

or near the first touch point of the circular stud. After you have

pressed the NC Start key, the TNC automatically probes the points

on the circle.
Move the touch probe to the next hole, repeat the probing

operation and have the TNC repeat the probing procedure until all

the holes have been probed to set the datum.