483

You can also use all manual touch probe cycles,

except the corner probing cycle, in Turning mode.

Observe that in Turning mode all measured data

in the X coordinate are calculated and displayed as

diameter values.
To use the touch probe in Turning mode you should

separately calibrate the touch probe in Turning mode.

Because the basic setting of the turning spindle in

Milling mode and Turning mode may deviate, you

should calibrate the touch probe without center

offset. You can create additional tool data for this

purpose, e.g. as an indexed tool.

For more information about the touch probe table,

refer to the User’s Manual for Cycle Programming.